NSSDCA ID: 1984-088A-03
Mission Name: AMPTE/CCEThe instrument consisted of an entrance collimator and electrostatic analyzer section followed by a time-of-flight and total-energy-measurement section floating at a 30 kV acceleration potential. The energy range covered was from 1 to 300 keV/Q, with a geometric factor of 2.E-3 sq cm-sr and 32-sector angular resolution. Energy resolution was 5 to 18%, and all charge states and isotopes of H and He, the charge states of Li, and the major elements and charge states up to and including Fe were resolved. For more details, see G. Gloeckler et al., IEEE Transactions on Geoscience and Remote Sensing, v. GE-23, p. 234, 1985.
Questions and comments about this experiment can be directed to: Coordinated Request and User Support Office
Name | Role | Original Affiliation | |
---|---|---|---|
Prof. George Gloeckler | Lead Investigator | University of Maryland | gg10@umail.umd.edu |
Dr. Berend Wilken | Other Investigator | Max-Planck-Institut fur Aeronomie | |
Dr. Dieter K. Hovestadt | Other Investigator | Max-Planck-Institut fur Extraterrestrische Physik | |
Dr. Fred M. Ipavich | Other Investigator | University of Maryland | fred@soho.umd.edu |
Dr. Gerhard Kremser | Other Investigator | Max-Planck-Institut fur Aeronomie | |
Dr. Wolfgang Studemann | Other Investigator | Max-Planck-Institut fur Aeronomie | |
Dr. Douglas C. Hamilton | Other Investigator | University of Maryland | dh7@umail.umd.edu |